*[https://hallaweb.jlab.org/wiki/images/8/80/Ejensen_corrdet_report.pdf Report] by E. Jensen on the rates in the coordinate detector.
 
*[https://hallaweb.jlab.org/wiki/images/8/80/Ejensen_corrdet_report.pdf Report] by E. Jensen on the rates in the coordinate detector.
* Study of resolution by Mark Jones
+
*[https://userweb.jlab.org/~jones/SBS/CDreport.pdf] Report] By L. Pentchev comparing the resolutions and rates for 5mm versus 3mm thick scintillators in the Coordinate Detector. [https://userweb.jlab.org/~jones/SBS/CDreport.tex Tex] version of the report.
**Point target with 4.4 +/- 0.2 GeV electrons. Front face of calorimeter is 526cm from target.
+
**3 planes of scintillator planes with 0.5cm thickness, 134cm long and 3cm width.
+
**each plane is 300 bars with the middle plane offset by .25cm
+
**15cm plastic absorber block in front.
+
** Throw electron for vertical and horizontal angle of +/-0.12 radians.
+
***[https://hallaweb.jlab.org/wiki/images/a/a6/Cdet_Eloss.gif Plot] of energy loss.
+
***[https://hallaweb.jlab.org/wiki/images/9/94/Cdet_Nbar.gif Plot ] of number of bars hit with 4 MeV threshold.
+
***[https://hallaweb.jlab.org/wiki/images/6/66/Cdet_Sigma.gif Plot] of Measured minus predicted vertical position.
+
** Tables of resolutions and efficiencies with different thresholds
+
{|class="wikitable" style="text-align: center" width="50%"
+
|-
+
!Threshold (MeV)
+
! Eff         
+
! sigma (mm)
+
|-
+
|3
+
|        0.90
+
|          1.01
+
|-
+
|4
+
|            0.89
+
|          0.98
+
|-
+
|4.5
+
|          0.87
+
|          0.95
+
|-
+
|5
+
|            0.84
+
|          0.94
+
|-
+
|5.5
+
|          0.75
+
|          1.02
+
|-
+
|6
+
|            0.63
+
|          1.06
+
|}
+

Revision as of 10:42, 27 June 2012

  • Report by E. Jensen on the rates in the coordinate detector.
  • [1] Report] By L. Pentchev comparing the resolutions and rates for 5mm versus 3mm thick scintillators in the Coordinate Detector. Tex version of the report.