Difference between revisions of "SBS HCal DAQ"
From Hall A Wiki
Line 1: | Line 1: | ||
*Start CODA | *Start CODA | ||
− | VTPTestFADC | + | log into triton |
+ | source coda_user_setup | ||
+ | start platform : rcplatform | ||
+ | start EB1 : | ||
+ | start ER1 : | ||
+ | |||
+ | on intelsbshcal1 : ./startroc10 | ||
+ | |||
+ | on triton : rcgui | ||
+ | choose VTPTestFADC | ||
+ | |||
+ | * readout files | ||
+ | |||
Line 34: | Line 46: | ||
VTP_CRATE end | VTP_CRATE end | ||
+ | |||
+ | |||
* FADC diagnostic tools | * FADC diagnostic tools |
Revision as of 15:31, 31 July 2017
- Start CODA
log into triton source coda_user_setup start platform : rcplatform start EB1 : start ER1 :
on intelsbshcal1 : ./startroc10
on triton : rcgui choose VTPTestFADC
- readout files
- Start and monitor VTP
- Notes
hostname VTP : sbsvtp1 hostname CPU : intelsbshcal1
- Cold start initialization
source go to vtp/test directory : execute ./vtpConfigTest hcalvtp.cnf
- Sample config file
VTP_CRATE all
VTP_FIRMWARE fe_vtp_halla_v7_hcal.bin
# slot: 10 13 9 14 8 15 7 16 6 17 5 18 4 19 3 20 # payload: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 VTP_PAYLOAD_EN 1 1 1 1 1 1 1 1 1 1 1 0 1 0 0 0
# maximum +/- coincidence (in ns) VTP_HCAL_HIT_DT 28
#threshold in calibrated ADC units VTP_HCAL_HIT_EMIN 10
VTP_CRATE end
- FADC diagnostic tools
- start server on intel CPU running the FADCs
cd diaggui_server DiagGuiServer
- on triton computer
cd fe_diaggui ./DiagGUI ROCConfigSBS.txt
- Problems