Difference between revisions of "Special Procedure For Moving Target"
From Hall A Wiki
(→Move target during production (automatic spin flip)) |
|||
Line 13: | Line 13: | ||
# Do '''Flip NOW''' | # Do '''Flip NOW''' | ||
# Turn '''OFF'''(pause) ''Auto Flip'' | # Turn '''OFF'''(pause) ''Auto Flip'' | ||
− | # | + | # Ask MCC to mask beam, then move target to new position |
− | * | + | * Ask MCC to mask beam, then move target to production ( He3 ) from other locations |
# Move target to He3 position for production | # Move target to He3 position for production | ||
# Turn '''ON'''(pause) ''Auto Flip'' | # Turn '''ON'''(pause) ''Auto Flip'' | ||
# Do '''Flip NOW''' | # Do '''Flip NOW''' | ||
# Once flip is done, start to take data | # Once flip is done, start to take data |
Revision as of 13:08, 18 November 2008
Move target while spin-up curve test
- NEVER move target during a sweep
- Time for next sweep can be estimated by adding wait time to last sweep time
Move target during production (automatic spin flip)
- NEVER move target during a flip
- Move target from production ( He3 ) to other locations
- If there is no production run since last flip, skip to step 4
- Stop current data taking
- Do Flip NOW
- Turn OFF(pause) Auto Flip
- Ask MCC to mask beam, then move target to new position
- Ask MCC to mask beam, then move target to production ( He3 ) from other locations
- Move target to He3 position for production
- Turn ON(pause) Auto Flip
- Do Flip NOW
- Once flip is done, start to take data