+ | == online analysis== | ||
+ | This section contains instructions for running the replay script with all detectors on a-onl@aonlX. | ||
+ | * Login to a-onl@aonlX (X=1, 2, 3, 4) | ||
+ | * once logged in, type ''gosbs'' => this takes you to the directory where the analysis should be done, and sets up the correct environment variables. | ||
+ | * open the analyzer by typing ''analyzer'' | ||
+ | * once in the analyzer type ''.L replay_gmn.C'' | ||
+ | * ''for routine analysis'' type ''replay_gmn(runnum, nevents)'', with: | ||
+ | ** ''runnum'' the run number you want to analyze; | ||
+ | ** ''nevents'' the number of events you want to analyze. | ||
+ | * ''for expert analysis only'' type ''replay_gmn(runnum, nevents, firstevent, file_prefix, firstsplit, nsplits, pedestalmode)'' with: | ||
+ | ** ''firstevent'' the event number from which you want to start the analysis; | ||
+ | ** ''file_prefix'' the prefix of the file you want to analyze; | ||
+ | ** ''firstsplit'' the split/segment number at which you want to start the analysis; | ||
+ | ** ''nsplits'' the number of splits/segments you want to analyze | ||
= Recovery Procedures = | = Recovery Procedures = |
Revision as of 10:55, 6 October 2021
Contents
Overview
This page gives instructions for various aspects of the experiment relating to each of the major subsystems and shift tasks.
Shift Roles
- Shift Leader: Executes the Run Plan according to the Run Coordinator's instructions
- Target Operator: Monitors the target system
- Data Quality Monitor: Starts and stops CODA DAQ runs and monitors the quality of the data that is being recorded
Reporting and Logging
All shift takers should regularly log shift details in HALOG - the Hall A electronic logbook.
Shift leaders should fill out Beam Time Accounting (BTA) information during the shift.
Taking Data
- Using the CODA DAQ
- GUI Description
- Starting a Run
- Stopping a Run
- Monitoring the data
- Online analysis
- Shift checklist
online analysis
This section contains instructions for running the replay script with all detectors on a-onl@aonlX.
- Login to a-onl@aonlX (X=1, 2, 3, 4)
- once logged in, type gosbs => this takes you to the directory where the analysis should be done, and sets up the correct environment variables.
- open the analyzer by typing analyzer
- once in the analyzer type .L replay_gmn.C
- for routine analysis type replay_gmn(runnum, nevents), with:
- runnum the run number you want to analyze;
- nevents the number of events you want to analyze.
- for expert analysis only type replay_gmn(runnum, nevents, firstevent, file_prefix, firstsplit, nsplits, pedestalmode) with:
- firstevent the event number from which you want to start the analysis;
- file_prefix the prefix of the file you want to analyze;
- firstsplit the split/segment number at which you want to start the analysis;
- nsplits the number of splits/segments you want to analyze
Recovery Procedures
Systems
High Voltage
Alarms
Beam Line
- Monitoring the Beam Line
- Hall A beam line drawing (to be updated)
- SBS checkout procedure
- SBS spot++ (beam size verification)
- SBS BPM calibration
- SBS HARP scan
- SBS Polarization Measurements
- Compton: Not Used
- SBS Moller
Target
Magnets
Detectors
BigBite
- GEMs
- GRINCH
- Timing Hodoscope
- Preshower and Shower
Super BigBite
- GEMs
- HCAL