Difference between revisions of "Polhe3 Metal Windows"
From Hall A Wiki
(New page: === Window Pressure Test Setup === * Investigating Larson glass to metal seals as means to couple metal windows to glass target chamber. * Pressure test setup assembled at UVa to test glas...) |
(→Window Pressure Test Setup) |
||
Line 5: | Line 5: | ||
{| | {| | ||
− | | [[Image:Ptest1_cp-100-T_16nov2011.jpg|thumb|upright|220px|.]] | + | | [[Image:Ptest1_cp-100-T_16nov2011.jpg|thumb|upright|220px|UVa pressure test setup for target windows. Larson CP-100-T glass to metal seal attached.]] |
− | | [[Image:Ptest2_cp-100-T_16nov2011.jpg|thumb|upright|220px|.]] | + | | [[Image:Ptest2_cp-100-T_16nov2011.jpg|thumb|upright|220px|Another view of pressure test setup. Larson CP-100-T glass to metal seal attached.]] |
− | | [[Image:Ptest3_cp-100-T_16nov2011.jpg|thumb|upright|220px|.]] | + | | [[Image:Ptest3_cp-100-T_16nov2011.jpg|thumb|upright|220px|Side view of pressure test setup, cardboard boxes and crate lid are open.]] |
− | | [[Image:Ptest4_cp-100-T_16nov2011.jpg|thumb|upright|220px|.]] | + | |} |
− | | [[Image:Ptest5_cp-100-T_16nov2011.jpg|thumb|upright|220px|.]] | + | {| |
− | | [[Image:Ptest6_cp-100-T_16nov2011.jpg|thumb|upright|220px|.]] | + | | [[Image:Ptest4_cp-100-T_16nov2011.jpg|thumb|upright|220px|Top view of pressure test setup with both cardboard boxes closed and weighed down with two half-thick fire bricks on top.]] |
− | | [[Image:Ptest7_cp-100-T_16nov2011.jpg|thumb|upright|220px|.]] | + | | [[Image:Ptest5_cp-100-T_16nov2011.jpg|thumb|upright|220px|Pressure test setup crate is fully closed.]] |
− | | [[Image:Ptest8_cp-100-T_16nov2011.jpg|thumb|upright|220px|.]] | + | | [[Image:Ptest6_cp-100-T_16nov2011.jpg|thumb|upright|220px|Pressure test setup blocked with protective wall and caution signs.]] |
− | | [[Image:Ptest9_cp-100-T_16nov2011.jpg|thumb|upright|220px|.]] | + | |} |
+ | {| | ||
+ | | [[Image:Ptest7_cp-100-T_16nov2011.jpg|thumb|upright|220px|High pressure gas delivery plumbing for test setup. Right to left: Regulator tank gauge, output gauge, shutoff valve. Nupro pressure relief valve. Test pressure gauge.]] | ||
+ | | [[Image:Ptest8_cp-100-T_16nov2011.jpg|thumb|upright|220px|Test pressure gauge P=140psig.]] | ||
+ | | [[Image:Ptest9_cp-100-T_16nov2011.jpg|thumb|upright|220px|Regulator gauges: Right to left: Tank pressure P=600psig. Output pressure P=137psig.]] | ||
|} | |} |
Revision as of 19:58, 29 November 2011
Window Pressure Test Setup
- Investigating Larson glass to metal seals as means to couple metal windows to glass target chamber.
- Pressure test setup assembled at UVa to test glas to metal seals at target cell operating pressures.
- Initial test on a Larson CP-100-T Pyrex glass to Copper metal seal performed on Nov 16 & 17, 2001. Test piece was pressurized to approximately 10-atm (137psig) of argon for 24hrs. The glass to metal seal did not explode.
File:Ptest8 cp-100-T 16nov2011.jpg Test pressure gauge P=140psig. |
File:Ptest9 cp-100-T 16nov2011.jpg Regulator gauges: Right to left: Tank pressure P=600psig. Output pressure P=137psig. |