Difference between revisions of "G2p Expert Shifts"

From Hall A Wiki
Jump to: navigation, search
(Information for Expert Shift Workers)
(Information for Expert Shift Workers)
Line 14: Line 14:
  
 
===Beamline===
 
===Beamline===
*Beam charge asymmetry  
+
*Check beam charge asymmetry
 +
**Check beam charge asymmetry for one run every 3~4 hours: type "asym L" or "asym R" or "asym TA" in adaq account, halog the result!
 
**Check charge asymmetry [https://hallaweb.jlab.org/wiki/index.php/Beam_charge_asymmetry_stripchart strip chart]
 
**Check charge asymmetry [https://hallaweb.jlab.org/wiki/index.php/Beam_charge_asymmetry_stripchart strip chart]
*Check for false asymmetry using [https://hallaweb.jlab.org/wiki/index.php/G2p_DAQ_How-To#How_to_start_xscaler_.28HRS.29_.2F_view_the_scalers scalers/lumis]
+
 
*check happex beam current asym: type "asym" or "asym L" or "asym R" in adaq account
+
 
*check BPM: type "spot++" or "spot_L" or "spot_R" in adaq account
 
*check BPM: type "spot++" or "spot_L" or "spot_R" in adaq account
  

Revision as of 14:42, 16 March 2012

Information for Expert Shift Workers

Below is a checklist of responsibilities for g2p student shift workers.

Here is the expert shift schedule

Student shift sun sheets

Run Information

  • Monitor deadtime, check that prescale values are appropriate
  • Monitor edtm scalers
  • Check that correct CODA configuration is being used
    • LHRS: LHRS
    • RHRS: RHRS

Beamline

  • Check beam charge asymmetry
    • Check beam charge asymmetry for one run every 3~4 hours: type "asym L" or "asym R" or "asym TA" in adaq account, halog the result!
    • Check charge asymmetry strip chart
  • check BPM: type "spot++" or "spot_L" or "spot_R" in adaq account
  • Monitor bleedthrough current

Target

  • Monitor target polarization
    • Check that TO is actively adjusting nmr to maximize polarization.
    • Check that target is moved to 2nd cup/annealed when polarization drops too low

Replay

  • Do full replay for every run (front room will only replay 20,000 events)
  • Check that all ROCs are getting gates