Difference between revisions of "Coordinate Detector"
From Hall A Wiki
Line 2: | Line 2: | ||
*[https://hallaweb.jlab.org/wiki/images/8/80/Ejensen_corrdet_report.pdf Report] by E. Jensen on the rates in the coordinate detector. | *[https://hallaweb.jlab.org/wiki/images/8/80/Ejensen_corrdet_report.pdf Report] by E. Jensen on the rates in the coordinate detector. | ||
* Study of resolution by Mark Jones | * Study of resolution by Mark Jones | ||
− | **Point target with 4. | + | **Point target with 4.4 +/- 0.2 GeV electrons. Front face of calorimeter is 526cm from target. |
**3 planes of scintillator planes with 0.5cm thickness, 134cm long and 3cm width. | **3 planes of scintillator planes with 0.5cm thickness, 134cm long and 3cm width. | ||
− | **each plane is 268 bars | + | **each plane is 268 bars with the middle plane offset by .25cm |
− | ** | + | **15cm absober block in front. |
− | ** Throw electron for vertical and horizontal angle of +/-0. | + | ** Throw electron for vertical and horizontal angle of +/-0.12 radians. |
***[https://hallaweb.jlab.org/wiki/images/a/a6/Cdet_Eloss.gif Plot] of energy loss. | ***[https://hallaweb.jlab.org/wiki/images/a/a6/Cdet_Eloss.gif Plot] of energy loss. | ||
− | ***[https://hallaweb.jlab.org/wiki/images/9/94/Cdet_Nbar.gif Plot ] of number of bars hit with | + | ***[https://hallaweb.jlab.org/wiki/images/9/94/Cdet_Nbar.gif Plot ] of number of bars hit with 4 MeV threshold. |
***[https://hallaweb.jlab.org/wiki/images/6/66/Cdet_Sigma.gif Plot] of Measured minus predicted vertical position. | ***[https://hallaweb.jlab.org/wiki/images/6/66/Cdet_Sigma.gif Plot] of Measured minus predicted vertical position. | ||
+ | ** | ||
+ | {| | ||
+ | |+Tables of resolutions and efficiencies with different thresholds | ||
+ | |- | ||
+ | |Threshold (MeV) | ||
+ | |Eff | ||
+ | |sigma (mm) | ||
+ | |- | ||
+ | |3 | ||
+ | | 0.90 | ||
+ | | 1.01 | ||
+ | |- | ||
+ | |4 | ||
+ | | 0.89 | ||
+ | | 0.98 | ||
+ | |- | ||
+ | |4.5 | ||
+ | | 0.87 | ||
+ | | 0.95 | ||
+ | |- | ||
+ | |5 | ||
+ | | 0.84 | ||
+ | | 0.94 | ||
+ | |- | ||
+ | |5.5 | ||
+ | | 0.75 | ||
+ | | 1.02 | ||
+ | |- | ||
+ | |6 | ||
+ | | 0.63 | ||
+ | | 1.06 | ||
+ | |} |
Revision as of 17:42, 4 June 2012
- Report by E. Jensen on the rates in the coordinate detector.
- Study of resolution by Mark Jones
- Point target with 4.4 +/- 0.2 GeV electrons. Front face of calorimeter is 526cm from target.
- 3 planes of scintillator planes with 0.5cm thickness, 134cm long and 3cm width.
- each plane is 268 bars with the middle plane offset by .25cm
- 15cm absober block in front.
- Throw electron for vertical and horizontal angle of +/-0.12 radians.
Threshold (MeV) | Eff | sigma (mm) |
3 | 0.90 | 1.01 |
4 | 0.89 | 0.98 |
4.5 | 0.87 | 0.95 |
5 | 0.84 | 0.94 |
5.5 | 0.75 | 1.02 |
6 | 0.63 | 1.06 |