Difference between revisions of "June 7, 2018"

From Hall A Wiki
Jump to: navigation, search
Line 39: Line 39:
 
<b>1. Discussion of GEANT4</b>
 
<b>1. Discussion of GEANT4</b>
  
Checked x-y hit distributions at various location using virtual planes in the simulation. Tried to track back the origin of the blob structure shown on the detector plane. Something weird shown at the Dipole exit.  
+
Checked x-y hit distributions at various location using virtual planes in the simulation. Tried to track back the origin of the blob structure shown on the detector plane. Something weird shown at the Dipole exit. Hit plots look rotated, but it's because of Solenoid field.
Asymmetric hit distributions on the left and right hodoscope planes when coincidence hits are required.
+
 
 +
Asymmetric hit distributions on the left and right hodoscope planes when coincidence hits are required. May come from asymmetric phi range in the generator.
 +
 
 +
Quad magnets seem to be not set well. Many particles hitting 3rd/4th quad shown from both G3 and G4. Stick with the same setting with Bill until we have better ones.
  
 
Suggestions: try check plots with Solenoid OFF. Set generated phi range symmetric.
 
Suggestions: try check plots with Solenoid OFF. Set generated phi range symmetric.

Revision as of 14:12, 7 June 2018

Back to Main Page >> Moller Page >> Moller Weekly Meeting Index

previous meeting << >> following meeting


Moller DocDB Meeting

Original Moller Polarimeter Page

Moller ELog


Connection details:


Meeting URL https://bluejeans.com/149766532

Meeting ID 149 766 532

US toll free phone 1.888.240.2560

Dial in, type in the meeting ID and then press ##



Agenda

  1. GEANT4 simulation update -Eric K [1]
  2. GEANT3 simulation update -Bill H [2]

Minutes

1. Discussion of GEANT4

Checked x-y hit distributions at various location using virtual planes in the simulation. Tried to track back the origin of the blob structure shown on the detector plane. Something weird shown at the Dipole exit. Hit plots look rotated, but it's because of Solenoid field.

Asymmetric hit distributions on the left and right hodoscope planes when coincidence hits are required. May come from asymmetric phi range in the generator.

Quad magnets seem to be not set well. Many particles hitting 3rd/4th quad shown from both G3 and G4. Stick with the same setting with Bill until we have better ones.

Suggestions: try check plots with Solenoid OFF. Set generated phi range symmetric.

2. Discussion of GEANT3



Attendees: Bill, Eric, Don, Dave, Rich, Simona, Cip, Kent, Sanghwa