Difference between revisions of "BBCAL Documents"
From Hall A Wiki
(→Detector Maps) |
|||
Line 12: | Line 12: | ||
==Detector Maps== | ==Detector Maps== | ||
− | *Shower elementID vs rows and columns numbers [[https://sbs.jlab.org/DocDB/0003/000300/001/sh_det_map.pdf link] | + | *Shower elementID vs rows and columns numbers [[https://sbs.jlab.org/DocDB/0003/000300/001/sh_det_map.pdf link]] |
− | *Preshower elementID vs rows and columns numbers [[https://sbs.jlab.org/DocDB/0003/000300/001/PS_detMap.pdf link] | + | *Preshower elementID vs rows and columns numbers [[https://sbs.jlab.org/DocDB/0003/000300/001/PS_detMap.pdf link]] |
==Cable Mapping at Front End== | ==Cable Mapping at Front End== |
Revision as of 13:44, 31 August 2022
Contents
- 1 BBCal Software
- 2 BigBite How-to
- 3 BBCal dimensions
- 4 Cable Layout in the Hall
- 5 Detector Maps
- 6 Cable Mapping at Front End
- 7 Cable Mapping at Weldment
- 8 High Voltage Mapping
- 9 Trigger Logic and Monitor
- 10 DAQ
- 11 BigBite Block Dimensions
- 12 Capacitative couplings to FIFO outputs
- 13 EDTM setup with the DVCS pulser
- 14 Study of the Linear Region of Operation for all the Electronic Modules
BBCal Software
- June 30th Presentation on Updates to the SBSGenericDetector
- Git repo with the start of BBShower software documentation
BigBite How-to
Adjusting High Voltage using GUI [pdf]
BBCal dimensions
- File with 3D and 2D CAD drawings of BB detector stack. Last page has relative z-distance of detectors.
Cable Layout in the Hall
Detector Maps
- Shower elementID vs rows and columns numbers [link]
- Preshower elementID vs rows and columns numbers [link]
Cable Mapping at Front End
Cable Mapping at Weldment
- BBCAL cable mapping original (xlsx)
- BBCal cable at FADCs (pdf)
- BBCal cable at Weldment patch panel (pdf)
High Voltage Mapping
Trigger Logic and Monitor
- Introduction to the BigBite Trigger Logic [link]
- Trigger Monitor Patch panels at Weldment and Front End (pdf)
- NIM to ECL units for trigger monitor (pdf)
- Trigger sums chart (png)
DAQ
- FADC Addresses (png)
- The position of the word matches the position of the switch, if the VME connector is on the right.
BigBite Block Dimensions
- BigBite shower and preshower block dimensions link
- Shower block layout that includes the position of old preshower blocks (png)
Capacitative couplings to FIFO outputs
- Information on capacitative couplings to FIFO outputs link
EDTM setup with the DVCS pulser
- EDTM setup with the DVCS pulser (png)
Study of the Linear Region of Operation for all the Electronic Modules
- Study of the Linear Region of Operation for all the Electronic Modules link