HV Control GUI
This GUI is used to enable/set particular voltage channels remotely.
- Log on to aslow@adaqsc
- cd slowc
- ./hvs BEAMLINE
This will start the GUI. Available channels should say "S1, S5, S6, S9, S12". Navigate to the table and select a channel. Make sure you know the desired voltage before proceeding. Check the box to enable, then click the HV On/Off on the left, if it is not already active.
These Photon Detector channels are for PREX/CREX running conditions:
Slot | Cha | HV | |
---|---|---|---|
Side (V) Finger | SL-6 | CH-10 | -950 V |
Top (H) Finger | SL-6 | CH-11 | -1000 V |
GSO (PhDetector) | SL-12 | CH-11 | See note 1 |
Note 1: For PRex the GSO is in an independent HV supply, set to -2340 V.
In addition, there are four scintillators in the laser table, two upstream and two downstream of the interaction point. Note: The following voltages are all positive.
Slot | Channel | HV | |
---|---|---|---|
DS Top | SL-9 | CH-0 | +1800 V |
DS Bottom | SL-9 | CH-1 | +1800 V |
US BR | SL-9 | CH-2 | +1800 V |
US BL | SL-9 | CH-3 | +1800 V |
Return to Compton
OLD INSTRUCTIONS
- Log on to adev@adaq1 or adev@adaq2.
- cd slowc
- ./hvs BEAMLINE
Old channel for PbWO4: Slot 12, Channel 11, set to about -1690V. (desired voltage as of 2016-11-10 to 2016-12-31)
Return to Compton