To turn a laser on:
  1. Be sure to connect the laser control box to the interlock and to the correct laser.
  2. Turn on the switch on the back panel of the laser.
  3. Turn the key on the front panel to turn on the power.
  4. Set the current through the keypad.
  5. Press the On/Off button. The screen should show 'laser enabled'.
  6. Press the On/Off button again. The screen should show 'laser on'. The laser should be on now.
To turn a laser off:

Table [*] lists the optimum parameter determined for the 30W lasers used in experiments E99-117 and E97-103 in the summer of 2001.


Table: Operational parameters for the 30W lasers.
Laser PS # FAP-I # Set Current Set Temperature Maximum Current $\star$
Coherent 1 3115 V7645 38500 mA 15 $^\circ$C 45000 mA
Coherent 2 4151 V7250 37000 mA 24 $^\circ$C 44600 mA
Coherent 3 4157 V7251 40000 mA 26.3 $^\circ$C 48000 mA
Coherent 4 4206 V8491 40000 mA 15.5 $^\circ$C 48000 mA
Coherent 5 4209 V8511 36000 mA 19.7 $^\circ$C 43200 mA
Coherent 6 4208 V8492 40000 mA 14.7 $^\circ$C 48000 mA
Coherent 7          
$\star$ Factory set absolute maximum current