Uh... cable?
A listing of crimp dies to use with which connectors and cable.
We use a variety of serial lines.
Patch Cables
Running from
Counting Room A
to
rack number 1H75B03 in Hall A.
- 50 ohm
- 75 ohm
- Twisted Pair
- Optical Fiber
Running from
rack number 1H75B03 in Hall A
into the
Electron arm detector hut.
- 50 ohm
- IEEE 802.3 10Base2 (isolated shield) - 2 cables
- DAQ ethernet
- Controls ethernet
- 75 ohm
- Cheap video cable (RG-59 "style") (isolated shield) - 2 cables
- Twisted Pair
- 1 bundle of 9 pairs (intended for DC voltages)
- 2 bundles of 17 pairs (intended for DC voltages) (unterminated)
- Optical Fiber
Running from
rack number 1H75B03 in Hall A.
to the
nose of the box beam on the Electron arm
Running from
the nose of the box beam on the Electron arm
into the Electron arm detector hut
Running from
rack number 1H75B03 in Hall A
into the
Hadron arm detector hut
- 50 ohm
- IEEE 802.3 10Base2 (isolated shield) - 2 cables
- DAQ ethernet
- Controls ethernet
- 75 ohm
- RG-59 (isolated shield) - 2 cables
- Twisted Pair
- 1 bundle of 17 pairs (intended for DC voltages)
- Optical Fiber
Running from
rack number 1H75B03 in Hall A
to the
nose of the box beam on the Hadron arm.
Running from
the nose of the box beam on the Hadron arm
into the Hadron arm detector hut
Running from
the second level of the Hadron arm electronics to the second
level of the Electron arm electronics
- 50 ohm
- RG-213 - 2 cables
- IEEE 802.3 10Base2 - 2 cables
- Twin-ax
Back to Jack's Notes