* Instructions for opening high voltage GUI for spectrometers
+
* Instructions for opening high voltage GUI for HRS
  
* login as '''adev''' on '''adaql1''' or  '''adaql2''' (eg: "'''ssh adev@adaql1'''")
+
* login as '''adev''' on '''adaq1''' or  '''adaq2''' (eg: "'''ssh adev@adaq1'''")
 
* passwords are written on the counting house white board
 
* passwords are written on the counting house white board
* To open Left and Right HRS HV GUI type "'''start_hvgui_hrs'''"  
+
* To open Left and Right HRS HV GUI type "'''hvgui_hrs'''"
** crate '''intelha3:2001''' is for LHRS  
+
* A VNC session of the HV GUI will open. If the VNC server is  off, then you can start it by doing "'''start_hvgui_hrs'''"  
** crates '''halladaq8:2001''' and''' ahut2:2001''' are for RHRS
+
** crate '''rpi8:2001''' is for LHRS  
** Never change HV values without an expert's approval (someone in the back room)
+
** crates '''rpi7:2001''' and''' rpi6:2001''' are for RHRS
 +
** Never change HV values without an expert's approval
  
  

Revision as of 13:26, 19 September 2014

  • Instructions for opening high voltage GUI for HRS
  • login as adev on adaq1 or adaq2 (eg: "ssh adev@adaq1")
  • passwords are written on the counting house white board
  • To open Left and Right HRS HV GUI type "hvgui_hrs"
  • A VNC session of the HV GUI will open. If the VNC server is off, then you can start it by doing "start_hvgui_hrs"
    • crate rpi8:2001 is for LHRS
    • crates rpi7:2001 and rpi6:2001 are for RHRS
    • Never change HV values without an expert's approval


[HV instructions for users]

[HV for experts]

12 GeV DVCS/GMp October 2014 running