All replay scipts and detectors calibration scripts can be found at /work/halla/e08014/disk1/yez/
 
All replay scipts and detectors calibration scripts can be found at /work/halla/e08014/disk1/yez/
 
+
**[[Analysis on ifarm]]
 
  1, ~/replay/,    replay script
 
  1, ~/replay/,    replay script
 
  2, ~/DB/,        data base  
 
  2, ~/DB/,        data base  
Line 63: Line 63:
 
  6, ~/onlineGUI,  online GUI.  
 
  6, ~/onlineGUI,  online GUI.  
 
     To check onlineGUI on ifarm, type: ./online -f HRS.cfg -r XXXX. 'online_C.so' still doesn't work.
 
     To check onlineGUI on ifarm, type: ./online -f HRS.cfg -r XXXX. 'online_C.so' still doesn't work.
  7, ~/batch_farm/, Submit jobs to ifarm
+
  7, ~/HRS/,        All detectors calibration directory.
    create your run list file, in which last line need to press 'ENTER'.
+
    Run './farm_cache' to cache raw data from silo,
+
    then run './gofarm' to submit jobs. 'gofarm2' is a better script to split one run replay into multi jobs but I am still working on it.
+
8, ~/HRS/,        All detectors calibration directory.
+
  
**[[Analysis on ifarm]]
 
 
**[[Job Submition on Batch Farm]]
 
**[[Job Submition on Batch Farm]]
 +
Scripts can be found in: ~/batch_farm/:
 +
1, Create your run list file, in which last line need to press 'ENTER'. Check the example, runlist.dat;
 +
2, Run './farm_cache' to cache raw data from silo. If the files in already in /cache/mss/halla/e07006/raw, skip this part;
 +
3, Then run './gofarm' to submit jobs. 'gofarm2' is a better script to split one run replay into multi jobs but I am still working on it.
 +
 
*[[HowTo for SRC family:]] [http://hallaweb.jlab.org/experiment/E07-006/howto.html HowTo]
 
*[[HowTo for SRC family:]] [http://hallaweb.jlab.org/experiment/E07-006/howto.html HowTo]
  
 
== Meetings ==
 
== Meetings ==

Revision as of 16:11, 18 March 2011

E08-014 : Three Nucleons Short Range Correlations at x>2

Experiment propusal

E08-014 web site

Spetrometers and Detectors

DAQ

Run Details

Analysis

How To Documentation

1, Login into adaq machines in counting house:
   [adaq@adaql2 $] ssh -X adaq@adaqlN (N=3~10, DONOT use adaql1,adaql2 for data analysis)
2, Go to Experiment Directory: (/adaqfs/home/adaq/e07006/onlana)
    [adaq@adaql10 $]goonlana
3, Run replay Script:
    [adaq@adaql10 $]analyzer 'replay_HRS.C(XXXX,50000)'  (XXXX is the run number)
4, Run OnlineGUI:
    [adaq@adaql10 $]analyzer
     analyzer [3]: online("HRS",XXXX) 
    

All replay scipts and detectors calibration scripts can be found at /work/halla/e08014/disk1/yez/

1, ~/replay/,     replay script
2, ~/DB/,         data base 
    must check that $DB_DIR points to this directory.
3, ~/Rootfiles/,  replayed data contained
4, ~/analyzer/,   Hall-A standard analyzer, which is currently updated to 1.5.22
5, ~/root_v5.26,  ROOT version 5.26 
    analyzer is compiled base on v5.26 so check your $ROOTSYS, or simply do: 'source SourceHereFirst'
6, ~/onlineGUI,   online GUI. 
    To check onlineGUI on ifarm, type: ./online -f HRS.cfg -r XXXX. 'online_C.so' still doesn't work.
7, ~/HRS/,        All detectors calibration directory.

Scripts can be found in: ~/batch_farm/:

1, Create your run list file, in which last line need to press 'ENTER'. Check the example, runlist.dat; 
2, Run './farm_cache' to cache raw data from silo. If the files in already in /cache/mss/halla/e07006/raw, skip this part;
3, Then run './gofarm' to submit jobs. 'gofarm2' is a better script to split one run replay into multi jobs but I am still working on it.

Meetings