Difference between revisions of "G2p shifts"
From Hall A Wiki
Line 5: | Line 5: | ||
* Expert contact [https://hallaweb.jlab.org/wiki/index.php/G2pcontacts list] and Expert [https://hallaweb.jlab.org/wiki/index.php/G2p_Expert_Shifts Shifts] | * Expert contact [https://hallaweb.jlab.org/wiki/index.php/G2pcontacts list] and Expert [https://hallaweb.jlab.org/wiki/index.php/G2p_Expert_Shifts Shifts] | ||
* Run Sheets ([http://hallaweb.jlab.org/experiment/g2p/shifts/Run-Sheet_g2p_B.pdf pdf]) and Shift [http://hallaweb.jlab.org/experiment/g2p/shifts/shift-check-list.pdf checklist] | * Run Sheets ([http://hallaweb.jlab.org/experiment/g2p/shifts/Run-Sheet_g2p_B.pdf pdf]) and Shift [http://hallaweb.jlab.org/experiment/g2p/shifts/shift-check-list.pdf checklist] | ||
+ | |||
+ | ==Shift Instructions == | ||
+ | * The septa current must be set to match each new spectrometer dipole momentum setting. | ||
+ | * Make sure to acknowledge the DAQ popup messages for Start and End of every run. | ||
+ | * Keep a stripchart running of the septa currents. Log <B>any</B> fluctuations, and notify Run Coordinator. | ||
+ | * Take bleedthru measurement once a shift | ||
+ | * Make sure you know exactly what you are doing if operating the Sieve Slit. Compare to this [http://hallaweb.jlab.org/halog/log/html/1204_archive/120412082759.html photo] | ||
==How Tos== | ==How Tos== | ||
Line 21: | Line 28: | ||
* Target [https://hallaweb.jlab.org/wiki/index.php/Target_Troubleshooting_Procedures Troubleshooting] and [https://hallaweb.jlab.org/wiki/index.php/Solid_Polarized_Target target overview] | * Target [https://hallaweb.jlab.org/wiki/index.php/Target_Troubleshooting_Procedures Troubleshooting] and [https://hallaweb.jlab.org/wiki/index.php/Solid_Polarized_Target target overview] | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
==Useful Links== | ==Useful Links== |
Revision as of 15:24, 13 April 2012
This page is updated frequently. Please hit Reload at least once per shift.
Contents
Basic Resources for Shift Workers
- Links: (Halog) (tlog)(g2pwiki) (ShiftSchedule) (MCC) (bta) (LSummary) (RSummary)
- Today's runplan
- Expert contact list and Expert Shifts
- Run Sheets (pdf) and Shift checklist
Shift Instructions
- The septa current must be set to match each new spectrometer dipole momentum setting.
- Make sure to acknowledge the DAQ popup messages for Start and End of every run.
- Keep a stripchart running of the septa currents. Log any fluctuations, and notify Run Coordinator.
- Take bleedthru measurement once a shift
- Make sure you know exactly what you are doing if operating the Sieve Slit. Compare to this photo
How Tos
- How to run the g2p DAQ
- How to Set the Spectrometer and Septa Magnets
- How to Cycle the Quadrupoles
- How to make vertical correction to target insert
- How to take HARP scan
- How to recover the beam after an extended (>4 hour) down: G2p-beam-recovery
- How to recover BPM positions after a long beam trip or tune change
- How to check Bleed-thru
- How to Set the Slow Raster
- How to check IHWP change in state and alarm
- How to control the Hall A Dump Camera Light
- How to run the Online Replay
- Target Troubleshooting and target overview
Useful Links
- The g2p Analysis Guide
- Beamline Component locations
- Chicane Positions
- MCC Whiteboard +offsite access to logs (courtesy Brad)
- d2n HowTo (Please note some info is out of date).
- Spring11 HowTo (Please note some info is out of date).
- Online Replay Guide (detailed) (Old Transversity Guide) (Please note some info is out of date).
- mysql Run Database for gep/g2p
- Hall A Moller
Miscellaneous Notes
- The Coda configuration is: LHRS, RHRS
- To read the Hall A current : Open Monticello / Wall / Hall A GUI, and look at the 1H00 BCM.
- To open the Hall A tools screen, as hacuser type "NewTools" which pops up EOSMenu. Select "HLAmain".
- To start a Stripchart, click toolbox on bottom of desktop menu
- Only IHWP1 flips the beam helicity. IHWP2 is passive.