Difference between revisions of "G2p shifts"
From Hall A Wiki
(→How Tos) |
(→Notes) |
||
Line 38: | Line 38: | ||
===Notes=== | ===Notes=== | ||
*PLEASE make sure to acknowledge the DAQ popup messages for Start and End of every run. | *PLEASE make sure to acknowledge the DAQ popup messages for Start and End of every run. | ||
− | |||
*The Coda configuration is: LHRS, RHRS | *The Coda configuration is: LHRS, RHRS | ||
*Hall A current : Open Monticello / Wall / Hall A GUI, and look at the 1H00 BCM. | *Hall A current : Open Monticello / Wall / Hall A GUI, and look at the 1H00 BCM. | ||
Line 44: | Line 43: | ||
*For Stripchart, click toolbox on bottom of desktop menu | *For Stripchart, click toolbox on bottom of desktop menu | ||
*Keep a stripchart running of the septa currents. | *Keep a stripchart running of the septa currents. | ||
− | *Note: IHWP1 flips the beam helicity. IHWP2 is passive (actually a full wave plate) and will not flip the helicity. | + | *Note: IHWP1 flips the beam helicity. IHWP2 is passive (actually a full wave plate) and will not flip the helicity. The epics var for IHWP2 is IGL1I00DIOFLRD :13056 means the passive wave-plate is in. 8960 is out.. |
Revision as of 14:49, 13 April 2012
This page is updated frequently. Please hit Reload at least once per shift.
(Halog) (tlog)(g2pwiki) (ShiftSchedule) (MCC) (bta) (LSummary) (RSummary)
How Tos
- How to make vertical correction to target insert
- How to take HARP scan
- How to recover BPM positions after a long beam trip or tune change
- How to recover the beam G2p-beam-recovery
- How to check Bleed-thru
- Target Troubleshooting and target overview
- How to Set the Spectrometer and Septa Magnets
- How to Cycle the Quadrupoles
- How to Set the Slow Raster
- How to check IHWP change in state and alarm
- How to control the Hall A Dump Camera Light
- How to run the Online Replay
- How to run the g2p DAQ
Useful Links
- The g2p Analysis Guide
- Beamline Component locations
- Chicane Positions
- MCC Whiteboard +offsite access to logs (courtesy Brad)
- d2n HowTo (Please note some info is out of date).
- Spring11 HowTo (Please note some info is out of date).
- Online Replay Guide (detailed) (Old Transversity Guide) (Please note some info is out of date).
- mysql Run Database for gep/g2p
- Hall A Moller
Notes
- PLEASE make sure to acknowledge the DAQ popup messages for Start and End of every run.
- The Coda configuration is: LHRS, RHRS
- Hall A current : Open Monticello / Wall / Hall A GUI, and look at the 1H00 BCM.
- For Hall A tools screen, on hacuser type "NewTools" which pops up EOSMenu. Select "HLAmain".
- For Stripchart, click toolbox on bottom of desktop menu
- Keep a stripchart running of the septa currents.
- Note: IHWP1 flips the beam helicity. IHWP2 is passive (actually a full wave plate) and will not flip the helicity. The epics var for IHWP2 is IGL1I00DIOFLRD :13056 means the passive wave-plate is in. 8960 is out..